Our new eBook will teach you the fundamentals and help you create monitors and alerts that are effective, meaningful, and actionable. Monitoring is more than a checkbox on your to-do list. This free eBook will give you practical advice to help you succeed in all aspects of monitoring – discovery, alerting, remediation, and troubleshooting. Don’t miss out on this indispensable resource for newbies, experienced IT pros, and everyone in between. Register Now.

Home > Success Center > Kiwi Syslog Server > Kiwi Syslog Server service is halting regularly

Kiwi Syslog Server service is halting regularly

Overview

The Kiwi Syslog Server service is halting every few hours or days with the following error in the Errorlog.txt file:

Error 9

Description: Subscript out of range
Module Name: syslogsvc.frm
Procedure name: ipdaemonS1_connected
Line number 10

Environment

  • All Windows versions
  • Kiwi Syslog Server 9.5

Resolution

Warning: Consult your System Administrator before performing this procedure.

  1. Run the Registry Editor and open the following key:
  2. Create a new string value with name InputTLSMaxConnections and set the value as 1000.
  3. Restart the Kiwi Syslog service.

Cause 

There are too many TCP connections.

 

Disclaimer: Please note, any content posted herein is provided as a suggestion or recommendation to you for your internal use. This is not part of the SolarWinds software or documentation that you purchased from SolarWinds, and the information set forth herein may come from third parties. Your organization should internally review and assess to what extent, if any, such custom scripts or recommendations will be incorporated into your environment.  You elect to use third party content at your own risk, and you will be solely responsible for the incorporation of the same, if any.

 