Get valuable help when it comes to tracking and monitoring changes. SolarWinds® Server Configuration Monitor (SCM) is designed to help you: detect, track, and receive alerts when changes occur, correlate system performance against configuration changes, compare server and application configuration against custom baselines, and verify application and system changes.

Learn more.

Home > Success Center > Kiwi CatTools > Kiwi Cat - Knowledgebase Articles > Error: invalid command config

Error: invalid command config

Updated August 26, 2016

Overview

A running configuration backup of an Enterasys Wireless Controller fails with the following error:

Error: invalid command "config". 

Environment

  • Kiwi CatTools 3.11

Cause 

There are differences in the Enterasys CLI commands for taking a configuration backup.

Resolution

To resolve this, the correct command needs to be updated in the device configuration:

  1. Open Kiwi CatTools.
  2. Select the Device and click Edit.
  3. Go to the Variations tab then click Use Variations.
  4. Select Additional Commands.
  5. Select the checkbox for Show Running Config.
  6. Change to the correct command for your device. Some examples are:
    • show run-config
    • show running-config
  7. Save the changes and run the activity again.

 

Last modified