Updated August 26, 2016


A running config backup of a Enterasys Wireless Controller fails with the following error:

Error: invalid command "config".


Kiwi CatTools 3.11


There are differences in the Enterasys CLI commands for taking a configuration backup.


To resolve this, the correct command needs to be updated in the device configuration:

  1. Open Kiwi CatTools.
  2. Select the Device and click Edit.
  3. Go to the Variations tab then click Use Variations.
  4. Select Additional Commands.
  5. Select the checkbox for Show Running Config.
  6. Change to the correct command for your device. Some examples are:
    show run-config
    show running-config
  7. Save the changes and run the activity again.