Overview

This article provides brief information and steps to resolve the following error within FoE when syncing FoE application with primary or secondary server, or during a failover or a switchover:

Orion FailOver Engine Out of Sync notification due to TFPTService.log

c:\programdata\solarwinds\logging\TFTPService.log 

 

Environment

  • All NPM versions
  • All FOE versions

 

Cause 

Since the TFTP service is not covered by FOE application and TFTP is installed on the FOE servers hence placed the logs under the Solarwinds folder which FOE application has to sync . 

 

FOE application failed to sync that log file as the TFTP service is running as normal and using the same Service log c:\programdata\solarwinds\logging\TFTPService.log therefore its failes.

 

Resolution

Create an Exclusion filter in FOE application as below: