Submit a ticketCall us

Looking to compare latest NPM features with previous versions of NPM?
The NPM new feature summary offers a comparison of new features and improvements offered with this release.

 

Home > Success Center > Failover Engine (FoE) > Orion FailOver Engine Out of Sync notification due to TFPTService.log

Orion FailOver Engine Out of Sync notification due to TFPTService.log

Created by Malik Haider, last modified by Aileen de Lara on Jun 29, 2016

Views: 6 Votes: 1 Revisions: 6

Updated June 29, 2016

Overview

This article provides brief information and steps to resolve the following error within FoE when syncing FoE application with primary or secondary server, or during a failover or a switchover:

Orion FailOver Engine Out of Sync notification due to TFPTService.log

c:\programdata\solarwinds\logging\TFTPService.log 

 

Environment

  • All NPM versions
  • All FOE versions

 

Cause 

Since the TFTP service is not covered by FOE application and TFTP is installed on the FOE servers hence placed the logs under the Solarwinds folder which FOE application has to sync . 

 

FOE application failed to sync that log file as the TFTP service is running as normal and using the same Service log c:\programdata\solarwinds\logging\TFTPService.log therefore its failes.

 

Resolution

Create an Exclusion filter in FOE application as below:

1. Go to Data > File Filters.

 

2. Click Add Exclusion Filter.

 

NOTE : Browse to the path, do not copy and paste the path.

 

 

 

 

 

 

Last modified
23:35, 28 Jun 2016

Tags

Classifications

Public