Join us from the 29th of January to the 2nd of February at Cisco Live 2018 in Barcelona, where we will continue to show how monitoring the network with SolarWinds will keep you ahead of the game. At our booth (WEP 1A), we will demonstrate how SolarWinds network solutions can help. As a bonus, we are also hosting a pre-event webinar - Blame the Network, Hybrid IT Edition with our SolarWinds Head Geek™, Patrick Hubbard on January 24th - GMT (UTC+0): 10:00 a.m. to 11:00 a.m. There's still time to RSVP.

Home > Success Center > Failover Engine (FoE) > HTTP service fails to stop and prevents the switchover from completing

HTTP service fails to stop and prevents the switchover from completing

Created by Mindy.Kerber, last modified by MindTouch on Jun 23, 2016

Views: 842 Votes: 1 Revisions: 5

Overview

This article provides brief information on the the HTTP service failing to stop and preventing a switchover from completing.

 

Environment

FoE all versions

 

Cause 

The SolarWinds Orion Toolset Integration service is not a protected service and does not start or stop from the Orion Failover Engine. If the SolarWinds Orion Toolset Integration service is not stopped, the HTTP service will fail to stop and prevent a switchover from completing.

 

Resolution

  1. Launch the Orion Failover Engine Manager.
  2. Go to the Applications: Services page.
  3. Click Add to create a new User Defined service.
  4. Select SWBrowserIntegration for the service to protect.
  5. Allow Orion Failover Engine to manage starting and stopping of the service.
  6. Click OK.

 

 

 

 