Overview

This article describes the issue in EOC when you receive this Configuration Wizard errors as below:

Error while executing script- Invalid column name 'C_WInterface'

 

The Configuration Wizard log displays the following:

INFO  ConfigurationProgressScene - Configuring core EOC database.
ERROR DBConfigProcessor - Error while executing script - Invalid column name 'C_WInterface'..
ERROR DBConfigProcessor - Failing Sql command: sp_refreshview 'EOC_Interface'
ERROR ConfigurationProgressScene - Error while executing script- Invalid column name 'C_WInterface'.

 

Environment

EOC version 1.6

 

Cause 

The issue may be due to a custom table having been added to the EOC table.

Resolution

Backup your database before making any direct changes.

  1. Log on to the SQL Server Connect and on to the DB using SQL Studio Management Console.
  2. Expand the EOC Database > Views > Select the View dbo.EOC_Interface.
  3. Right-click the file and select Delete.
  4. Re-run the EOC Configuration Wizard.
 

 

Last modified

Tags

Classifications