Learn how help desk software can simplify ticketing management, allow you to track hardware and software assets, and accelerate the speed of IT support and service delivery. Gain insights on how remote support tools allow your IT team to maximize their efficiency and ticket resolution by expediting desktop troubleshooting, ultimately helping keep end-users happy and productive.

Register here.

Home > Success Center > Enterprise Operations Console (EOC) > EOC - Knowledgebase Articles > EOC Web Console error: There is a problem with the module polling

EOC Web Console error: There is a problem with the module polling

Created by Michael Perez, last modified by Laura C on Jan 03, 2018

Views: 1,808 Votes: 0 Revisions: 5

Overview

The EOC Web Console displays the following error:

There is a problem with the <moduleName> module polling at the <serverName> SolarWinds Server. For additional information, see KB4124.

Note: The error message references a Knowledge Base article number from our legacy system.

Environment

  • All supported versions of EOC

Cause 

There are three potential causes for this error:

  • EOC is polling an unsupported version of the module.
  • EOC has lost its connection to the server it was polling.
  • The credentials for the Orion server are not valid.

Resolution

  1. Verify that EOC is polling only supported modules.
  2. Verify that all of the SolarWinds servers EOC monitors are operational.
  3. Verify that the connections between your EOC server and the SolarWinds servers it monitors are operational.
  4. Verify that the EOC services are all in a Started state.
  5. Test the credentials for the Orion server listed in the error under Settings> Manage SolarWinds Servers.
  6. If the test fails and other causes have been ruled out, update the Orion server's credentials.

 