Submit a ticketCall us

WebinarDatabase Roundtable – Expert Database Professionals Feel Your Pain

In this video broadcast, Head Geek™ Tom LaRock is joined by Karen Lopez, Tim Chapman, and David Klee. They’ve known each other for many years, so this discussion was like four friends getting together to talk data and databases. They discussed diagnostic data collection, common performance root causes, reactive tuning versus proactive, and more. Join us for an engaging discussion on these topics! Plus, Tom LaRock will be available to answer your questions live.

Register now.

Home > Success Center > Enterprise Operations Console (EOC) > EOC - Knowledgebase Articles > Could not use view or function 'EOC_Volume' because of binding errors

Could not use view or function 'EOC_Volume' because of binding errors

Created by Norsolihati Selamat, last modified by Laura C on Oct 31, 2017

Views: 1,166 Votes: 0 Revisions: 10

Overview

After migrating your database from SQL Server 2005 to SQL Server 2008, you may receive a Configuration Wizard error similar to the following:

ERROR ConfigurationProgressScene - Error while executing script-Invalid column name 'AdminEmailVolumes'.
Invalid column name 'Service'.
Could not use view or function 'EOC_Volume' because of binding errors.

 

Environment

All EOC versions

Resolution

Note: Make sure a good database backup has already been done before making direct changes to the database.

  1. Open SQL Management Studio.
  2. Expand to Orion EOC database > Views.
  3. Delete the EOC_Volume view.
  4. Re-run the Configuration Wizard.

 

Last modified