Our new eBook will teach you the fundamentals and help you create monitors and alerts that are effective, meaningful, and actionable. Monitoring is more than a checkbox on your to-do list. This free eBook will give you practical advice to help you succeed in all aspects of monitoring – discovery, alerting, remediation, and troubleshooting. Don’t miss out on this indispensable resource for newbies, experienced IT pros, and everyone in between. Register Now.

Home > Success Center > Enterprise Operations Console (EOC) > Error while executing script- Column name or number of supplied values does not match table definition

Error while executing script- Column name or number of supplied values does not match table definition

Created by Norsolihati Selamat, last modified by Rodim Suarez on Sep 07, 2016

Views: 30 Votes: 0 Revisions: 4

Overview

The following error message appears after running Configuration Wizard during an upgrade from 1.6.1 to 1.6.2:
Error while executing script- Column name or number of supplied values does not match table definition.

 

Upon launching the EOC Web Console, it displays the following error below:

The system cannot find the file specified. (Exception from HRESULT: 0x80070002)

 

Example:

Bsed on the installer logs,  observed the below error in EOC_1.6.2_install_log.txt:

EOC [10:37: 4:292] : Entry .. .. ProcessSetupChain
EOC [10:37: 4:292] : Entry .. .. .. DetectMsi
EOC [10:37: 4:292] : FAIL  .. .. .. ..minor upgrade
EOC [10:37: 4:292] : Exit  .. .. .. DetectMsi FAILED 0x8000FFFF
EOC [10:37: 4:292] : Entry .. .. .. ConfigureMsi
EOC [10:37: 4:292] : INFO  ..CONFIGURE_ACTION_MINOR_UPGRADE
EOC [10:37: 4:323] : Exit  .. PrepareThread
EOC [10:38:27:912] : Exit  .. .. .. ConfigureMsi
EOC [10:38:27:912] : FAIL  .. .. ..Failed to launch and wait for cached MSI: C:\ProgramData\SolarWinds\EOC\EXEs\SolarWinds-EOC.msi.
EOC [10:38:27:912] : Exit  .. .. ProcessSetupChain FAILED 0x80070669
EOC [10:38:27:912] : FAIL  ..Failed to install main msi.
EOC [10:38:27:912] : Exit  WinMain FAILED 0x80070669

Environment

EOC 1.6.x

Resolution

  1. Completely uninstall EOC from the server.
  2. Re-install EOC 1.6.2

 

Last modified

Tags

Classifications

Public