Issue:

If you uninstall SolarWinds Orion Core Services from the Control Panel, and then click Add alert action in Toolset Network Performance Monitor, the Select an Action for this Alert window is not displayed.

Resolution:

  1. Run cmd.exe from the Start menu.
  2. Type the following text: regsvr32 "<yourtoolsetinstallationfolder>\SWAlertActions.dll"</yourtoolsetinstallationfolder>. By default, the Toolset Installation Folder is C:\Program Files\SolarWinds\Toolset.
  3. Press Enter.