Overview

This article describes how to set DPA to only use traffic over HTTPS (8124 by default).

Environment

All DPA versions

Steps

  1. Go to <DPAInstallDirectory>\iwc\tomcat\conf\.
  2. Create a backup of the server.xml file.
  3. Comment out the HTTP connector section:
    <!-- HTTP connector
        <Connector port="8123" maxHttpHeaderSize="20480" URIEncoding="UTF-8" compression="on"
                   compressionMinSize="2048" compressableMimeType="text/html,text/xml,text/csv,text/css,text/javascript"
        /> -->
  4. Save the file.
  5. Restart the Ignite PI service.

 

 