Submit a ticketCall us

Looking to compare latest NPM features with previous versions of NPM?
The NPM new feature summary offers a comparison of new features and improvements offered with this release.

 

Home > Success Center > Database Performance Analyzer (DPA) > Stack trace IO Error: Got minus one from a read call

Stack trace IO Error: Got minus one from a read call

Table of contents

Updated March 11th, 2016

Symptom

You get an error when you try to register an Oracle RDS database. Or, a registered Oracle RDS instance monitor shuts down. The error may look something like this:

Monitor for database [DATABASENAME] failed in job [QuickPollJob] due to [could not connect to monitored database]. Will attempt to retry every [60] seconds...org.quartz.JobExecutionException: QuickPollJob failed [See nested exception: org.springframework.jdbc.CannotGetJdbcConnectionException: Could not get JDBC Connection; nested exception is java.sql.SQLException: IO Error: Got minus one from a read call]

Issue

The Oracle database has hit the process limit and needs more processes.

Workaround

Increase the process limit of the monitored database. If the Oracle database uses the SPFILE for configuration, you can edit the file to increase the limit. Example:

alter system set processes = 200 scope=spfile;

Last modified
14:09, 7 Apr 2017

Tags

Classifications

Public