Join us from the 29th of January to the 2nd of February at Cisco Live 2018 in Barcelona, where we will continue to show how monitoring the network with SolarWinds will keep you ahead of the game. At our booth (WEP 1A), we will demonstrate how SolarWinds network solutions can help. As a bonus, we are also hosting a pre-event webinar - Blame the Network, Hybrid IT Edition with our SolarWinds Head Geek™, Patrick Hubbard on January 24th - GMT (UTC+0): 10:00 a.m. to 11:00 a.m. There's still time to RSVP.

Home > Success Center > Database Performance Analyzer (DPA) > Stack trace IO Error: Got minus one from a read call

Stack trace IO Error: Got minus one from a read call

Table of contents

Updated March 11th, 2016

Symptom

You get an error when you try to register an Oracle RDS database. Or, a registered Oracle RDS instance monitor shuts down. The error may look something like this:

Monitor for database [DATABASENAME] failed in job [QuickPollJob] due to [could not connect to monitored database]. Will attempt to retry every [60] seconds...org.quartz.JobExecutionException: QuickPollJob failed [See nested exception: org.springframework.jdbc.CannotGetJdbcConnectionException: Could not get JDBC Connection; nested exception is java.sql.SQLException: IO Error: Got minus one from a read call]

Issue

The Oracle database has hit the process limit and needs more processes.

Workaround

Increase the process limit of the monitored database. If the Oracle database uses the SPFILE for configuration, you can edit the file to increase the limit. Example:

alter system set processes = 200 scope=spfile;

Last modified

Tags

Classifications

Public