Home > Success Center > Customer Service > Configuration Wizard: Exception while configuring plugin Orion Core Services component Message Bus. Invalid provider type specified

Configuration Wizard: Exception while configuring plugin Orion Core Services component Message Bus. Invalid provider type specified

Table of contents

Updated September 18th, 2017

Overview

This articles describes an issue some users may run into when upgrading Modules to the latest versions.


ERROR ConfigurationProgressScene - Exception while configuring plugin Orion Core Services component Message Bus. System.Security.Cryptography.CryptographicException: Invalid provider type specified.

  

Environment

  • NPM 12.0+
  • SAM 6.3+

Detail

 

  1. On the Orion Server - Log in with a Local Administrator Account (Non-Domain). 
     
  2. Navigate to: C:\ProgramData\Microsoft\Crypto\Rsa\
     
  3. Give the MachineKey folder the permissions below, and then run configuration wizard again.
    PLEASE NOTE: These permissions are mandatory and must be in place. All of them must be set as documented below.
    Administrators	 (Full Control)
    
    Everyone	         (Special)	
    
    To view the special permissions for the Everyone group,
    		  right-click the MachineKeys folder, click
    		  Advanced on the Security tab, and then click
    		  View/Edit. The permissions consist of the following
    		  permissions: List Folder/Read Data
    
    Read Attributes
    Read Extended Attributes
    Create Files/Write Data
    Create Folders/Append Data
    Write Attributes
    Write Extended Attributes
    Read Permissions		 
 

 