The SolarWinds Renewal Program comes with a host of benefits including the most recent product updates, 24/7 technical support, virtual instructor-led training and more. Experience all of this with the convenience of Auto Renewal, and never worry about missing any of these great benefits. Learn More.

Home > Success Center > Archive > 2017October17 - Cleanup > Unable to update Operation information in VNQM

Unable to update Operation information in VNQM

Created by Andy Ng, last modified by Gerald.Prado on Oct 17, 2017

Views: 19 Votes: 0 Revisions: 5

Updated June 24, 2016

Overview

This article addresses the issue where updated Operation information is reverted to the previous value after editing and modifying.

Environment

VNQM 4.1

Cause 

SNMP Read/Write community strings are required for VNQM to update Operation information within the application itself.

Resolution

  1. Log in to the Orion Web Console.

  2. Go to Settings > Manage Nodes.

  3. Select the affected Nodes.

  4. Click Edit Properties.

  5. Enter Read/Write Community String: and leave Community String: blank.

  6. Test and verify that it works.

  7. Make the changes to the Operations.

 