Submit a ticketCall us

Solarwinds & Cisco Live! Barcelona
Join us from the 29th of January to the 2nd of February at Cisco Live 2018 in Barcelona, where we will continue to show how monitoring the network with SolarWinds will keep you ahead of the game. At our booth (WEP 1A), we will demonstrate how SolarWinds network solutions can help. As a bonus, we are also hosting a pre-event webinar - Blame the Network, Hybrid IT Edition with our SolarWinds Head Geek™, Patrick Hubbard on January 24th - GMT (UTC+0): 10:00 a.m. to 11:00 a.m. There's still time to RSVP.

Home > Success Center > Archive > 2017December27 - Deletes > No CBQoS Data After Moving Devices to Additional Poller

No CBQoS Data After Moving Devices to Additional Poller

Created by Con Finucane, last modified by Jessica Solis on Dec 27, 2017

Views: 635 Votes: 1 Revisions: 5

Overview

This article provides brief information on the issue when no CBQoS data is received after moving devices to additional pollers. 

Environment

All NTA versions

Cause 

NTA needs to be installed on the additional poller server to allow the CBQoS poller to be assigned to the nodes.

Resolution

On the additional poller, install the NTA version that matches the version of the NTA on the main poller.

 

 

 

Last modified

Tags

Classifications

Public