The SolarWinds Renewal Program comes with a host of benefits including the most recent product updates, 24/7 technical support, virtual instructor-led training and more. Experience all of this with the convenience of Auto Renewal, and never worry about missing any of these great benefits. Learn More.

Home > Success Center > Archive > 2017December12 - Deletes > Data processor errors and VNQM performance issues

Data processor errors and VNQM performance issues

Created by Daniel Phillipps, last modified by Kevin.Swinson on Dec 12, 2017

Views: 717 Votes: 0 Revisions: 5

Overview

This article describes the issues with VNQM performance as well as the following error message that shows up in the Data processor logs:

2016-03-09 08:56:44,481 [STP DatabaseProcessing Thread #1568] ERROR SolarWinds.Orion.IpSla.Collector.DAL.CCM.ResultHandler - ccmGateway Table. [Index=449]
System.Data.SqlClient.SqlException (0x80131904): String or binary data would be truncated.

Environment

VNQM version 4.2.x

Cause 

The error is caused by issues with the actual Gateways being monitored in VNQM.

Resolution

  • Check the Gateways by going to Settings > VNQM > Manage Gateways.
  • Check the credentials and make sure none of them are failing for CLI.
  • Verify that VNQM is loaded on all the pollers.

 