Network Management

How to install an additional polling engine - Video

This article provides a video that can teach more about installing additional polling engine. This information is for the Orion Platform version 2016 and above. Products on this Orion Platform version include Network Performance Monitor (NPM) 12.0 and later and SAM 6.2.4 and later.

First published date

11/15/2018 9:19 PM

Last published date

11/16/2026 7:17 PM

Overview

This video demonstrates how to install an additional polling engine.

 

Product section

Orion Platform

Resolution

Related Resources

Video Transcript

In this video, we’re going to walk through the steps to install an additional polling engine and connect it to your main Orion platform server.

Before you get started, you should first ensure that your Orion platform environment has been fully updated, and of course, double-check the system requirements to help ensure your new polling engine server will be up to its task.

You should also gather the SQL server details and credentials for where your Orion platform database is stored, as you will need them later.

Log in to your customer portal, and look for the Additional polling engine package, then download the latest version to the newly created server.

Run the additional polling engine installer. Enter the IP address of the main server, then click 'Next.'

Specify the new server's role. You can choose between Additional Polling Engine, Additional Website, or High Availability for your Main Server or Additional Polling Engine. For this demo, let's choose Additional Polling Engine. Specify the destination folder, then click 'Next.'

The Setup Wizard will now run tests against your system to help ensure that it meets all the requirements. It will alert you to any potential configuration problems that it finds. For example, if your server does not meet minimum specs or you are trying to install on a Domain Controller, the installer will block and prevent your installation. The installer could also find warning issues, such as not enough CPU or RAM. In this case, the installer will warn you but not block the install. You can choose to cancel the installation or continue, knowing that server performance may be affected. If you don't see any warning messages, that means your system passed all the tests with no issues.

Read and accept the terms of the End User License Agreement, then click 'Next' to begin the installation.

Once the installation is complete, the configuration wizard will start automatically. When prompted, enter the information for the same SQL instance and SQL database that was chosen for the primary server installed on the Orion Platform.

Click Finish to complete the installation of the Additional Polling Engine.

Your additional polling engine is ready to poll, but you’ll need to configure it to determine what it should poll.

If you want to move a number of existing nodes over to your new polling engine to balance the polling load, navigate to Manage Nodes, and select the nodes you want to move. Use the ‘Change Polling Engine’ option from the drop-down menu and choose the polling engine you would like to move these nodes to. You should always exercise caution when making changes like this, as there may be firewalls or security defined on your nodes or the network path allowing polling communication only from the main polling engine. Make sure any environmental adjustments have been made before migrating your nodes.

With an additional polling engine installed, you'll also have the option to run a discovery specifically from that engine. You’ll notice that in a multi-poller environment, you have the option to run the discovery from the polling engine of your choice.

To activate your Additional Polling Engine License, navigate to License Manager from the Orion Web Console. Click 'Add/Upgrade License.' Enter your activation key and registration information, and then click 'Activate.'


 

Instructions: Installing and Configuring an Additional Polling Engine (APE)

1. Prerequisites and Preparation

Before starting the installation, ensure that the following requirements are met:

  1. Verify that your existing Orion Platform environment is fully updated.

  2. Review the system requirements to ensure that the new server meets the minimum hardware and software specifications.

  3. Prepare a newly provisioned server dedicated to the Additional Polling Engine (APE).

  4. Gather the following SQL database information:

    • SQL Server hostname or IP address.

    • SQL Instance name, if applicable.

    • Orion Platform database name.

    • Required SQL credentials and authentication details.

  5. Ensure that the necessary network connectivity and firewall rules are configured between the Main Polling Engine, Additional Polling Engine, and SQL Server.

2. Download the Additional Polling Engine Installer

  1. Log in to the SolarWinds Customer Portal.

  2. Navigate to the available software downloads.

  3. Locate the Additional Polling Engine installation package.

  4. Download the latest available installer.

  5. Copy or save the installer to the newly provisioned APE server.

3. Run the Additional Polling Engine Installer

  1. Log in to the newly provisioned server.

  2. Locate and run the Additional Polling Engine installer.

  3. When prompted, enter the IP address of the existing Main Polling Engine.

  4. Click Next.

4. Select the Server Role

  1. Specify the role of the new server.

  2. Select the appropriate installation type from the available options:

    • Additional Polling Engine

    • Additional Website

    • High Availability for Main Server or Additional Polling Engine

  3. For this installation, select Additional Polling Engine.

  4. Specify the destination installation folder.

  5. Click Next.

5. Review System Requirements and Validation

The Setup Wizard will automatically perform system checks to verify whether the server meets the installation requirements.

Review the results carefully:

  • Blocking issues: These indicate that the server does not meet mandatory installation requirements. For example, insufficient minimum specifications or attempting to install on a Domain Controller. These issues must be resolved before proceeding.

  • Warning issues: These indicate potential performance or configuration concerns, such as insufficient CPU or RAM resources. The installation may proceed, but server performance could be affected.

  • No warnings or errors: The server has successfully passed the system validation checks.

If warnings are displayed, evaluate and address them before proceeding with the installation.

6. Accept the License Agreement and Install

  1. Review the End User License Agreement (EULA).

  2. Accept the terms and conditions.

  3. Click Next to begin the installation.

  4. Allow the installer to complete the installation process.

7. Configure the Additional Polling Engine

Once the installation is complete, the Configuration Wizard will automatically launch.

  1. When prompted, provide the SQL Server information.

  2. Specify the same SQL Server instance and Orion Platform database used by the Main Polling Engine.

  3. Enter the required SQL credentials.

  4. Follow the remaining Configuration Wizard prompts.

  5. Review the configuration settings.

  6. Click Finish to complete the configuration.

At this point, the Additional Polling Engine should be successfully installed and connected to the existing Orion Platform environment.

8. Assign Nodes to the Additional Polling Engine

After installation, configure which network devices and nodes the new polling engine will monitor.

To transfer existing nodes from the Main Polling Engine:

  1. Log in to the Orion Web Console.

  2. Navigate to Manage Nodes.

  3. Select the nodes you want to move to the Additional Polling Engine.

  4. Open the available actions drop-down menu.

  5. Select Change Polling Engine.

  6. Choose the newly installed Additional Polling Engine.

  7. Apply the changes.

Important considerations before migrating nodes:

  • Verify that the necessary firewall rules are configured.

  • Ensure that the new polling engine can communicate with the devices being monitored.

  • Review any network security restrictions that may allow polling communication only from the Main Polling Engine.

  • Confirm that all required network paths and permissions are in place before migrating nodes.

9. Run Network Discovery Using the Additional Polling Engine

In a multi-poller environment, you can also run network discovery using a specific polling engine.

  1. Navigate to the Network Discovery section.

  2. Start a new discovery or edit an existing discovery profile.

  3. Select the polling engine you want to use for the discovery.

  4. Choose the newly installed Additional Polling Engine.

  5. Configure the discovery settings and proceed with the discovery process.

This allows you to distribute discovery activities across your available polling engines.

10. Activate the Additional Polling Engine License

To activate the APE license:

  1. Log in to the Orion Web Console.

  2. Navigate to License Manager.

  3. Click Add/Upgrade License.

  4. Enter your Additional Polling Engine activation key.

  5. Provide the required registration information.

  6. Click Activate.

  7. Verify that the license has been successfully activated.

 

Final Verification Checklist

After completing the installation, verify the following:

  • Additional Polling Engine installation completed successfully.
  • Configuration Wizard completed without errors.
  • APE is connected to the same Orion Platform database as the Main Polling Engine.
  • Additional Polling Engine is visible in the Orion Web Console.
  • APE license has been activated successfully.
  • Required firewall rules and network connectivity are confirmed.
  • Nodes have been assigned to the appropriate polling engine, if applicable.
  • Polling activity and data collection are functioning as expected.

Expected Result: The Additional Polling Engine is successfully installed, connected to the existing Orion Platform environment, licensed, and ready to monitor assigned network devices.