Network Management
Custom poller returns incorrect values
This article describes how to update the poller type so that UDP returns the correct values.
First published date
Last published date
Overview
Product section
Cause
Resolution
MIB values and tables are classified by data types. These values are normally stated in the OID details of the respective MIB values and tables. To retrieve the correct values, UDP must be set to the correct poller type. The Universal Device Poller offer three different poller types:
- Rate – Uses the data types: Integer, UInteger, UnsignedInteger32, Gauge, and Gauge32.
- Counter - Uses the data types, Counter, Counter32, and Counter 64.
- Raw Value - Returns the raw value of the OID being polled.
These options can be adjusted by clicking the Show Advanced Options button on “Define Your Universal Device Poller.”